【簡(jiǎn)介】
鋼板上的六價(jià)鉻通常采用沸水或堿進(jìn)行萃取,調(diào)節(jié)萃取液的pH后加入顯色劑,顯色后用紫外一可見(jiàn)分光光度計(jì)測(cè)定。目前國(guó)內(nèi)外關(guān)于六價(jià)鉻的測(cè)試標(biāo)準(zhǔn)主要有:IS0 3613:2001 Chromate conversion coatings on zinc。 cadmium,aluminium-zinc alloys and zinc-aluminium nlloys-Test method,EPA 3060A Rev.1:1 996 AIkaline digestion for hexavalent chromium EPA 7196A Rev.1:1992 Chromium, hexavalent(colorimetric),BS EN l 5205:2006 Determination of hexavalent chromium in corrosion protection laIyers— Qualitative analysis,IEC 62321 Ed.1(1 1 1/95/CDV) Electrotechnical products--Determination oflevels ofsix regulated substances(1ead,mercury,cadmium,hexavalent chromium,polybrominated biphenyls,polybrominated diphenylethers),JIS H 8625:1993 1 (電鍍鋅和電鍍鎘層的鉻酸鹽轉(zhuǎn)化膜),SJ/T l l365-2006《電子信息產(chǎn)品中有毒有害物質(zhì)的檢測(cè)方法》,GB/T 9791—2003《鋅、鎘、鋁一鋅合金和鋅一鋁合金的鉻酸鹽轉(zhuǎn)化膜試驗(yàn)方法》等。各標(biāo)準(zhǔn)在萃取時(shí)間、萃取劑、溫度、結(jié)果表示等方面都存在差異,如表1所示。由表1可知,這些標(biāo)準(zhǔn)方法之間也存在完全等效(如IS0 3613與 GB/T 9791)或部分等效(OH IS0 3613與JIS H 8625)。
表1各種六價(jià)鉻檢測(cè)標(biāo)準(zhǔn)的比較
Table l Comuarison between various standards for determininp hexavalent chromium

”“含有”即positive(陽(yáng)性),“不含有”即negative(陰性)。2’UV—vis即“紫外一可見(jiàn)分光光度法”。
鋼板涂鍍層中六價(jià)鉻含量的測(cè)定方法比較
萃取條件對(duì)六價(jià)鉻測(cè)定結(jié)果的影響(一)
萃取條件對(duì)六價(jià)鉻測(cè)定結(jié)果的影響(二)
鋼板涂鍍層中六價(jià)鉻含量的測(cè)定方法比較:討論(一)
鋼板涂鍍層中六價(jià)鉻含量的測(cè)定方法比較:討論(二)
鋼板涂鍍層中六價(jià)鉻含量的測(cè)定方法比較:結(jié)語(yǔ)